Veris E50H2A

$558.93

The E50H2A BACnet MS/TP DIN Rail Meter combines exceptional performance and easy installation to deliver a cost-effective solution for power monitoring applications. Native serial communication via BACnet MS/TP provides complete accessibility of all measurements to your Building Automation System. Built in integrator and power supply for U018 CTs. The E50H2A can be easily installed on standard DIN rail, surface mounted or contained in an optional NEMA 4 enclosure, as needed. The front-panel LCD display makes device installation and setup easy and provides local access to the full set of detailed measurements. A phase alarm pulse output provides additional versatility and a pulse input provides an easy way to incorporate a simple flow sensor to track gas, water, steam, or other energy forms using a BACnet building automation system in addition to full monitoring of electrical energy.
APPLICATIONS

  • Energy monitoring in building automation systems
  • Energy management
  • Commercial submetering
  • Industrial monitoring
  • Cost allocation
    FEATURES

  • Built in integrator and power supply for U018 CTs
  • DIN rail mounting option…easy installation
  • ANSI 12.20 0.5% accuracy, IEC 62053-22 Class 0.5S…great for cost allocation
  • Separate pulse input and phase loss alarm output…one device serves multiple applications
  • 90-600 VAC…application versatility with fewer models to stock
  • Bright backlit LCD…easy visibility in dark enclosures
  • Compatible with Veris U018 CTs from 20A to5000A…wide range of service types
  • User-enabled password protection…protect from tampering
  • System integration via BACnet MS/TP…convenient compatibility with existing systems
  • Native BACnet MS/TP support (no gateway) with serial rates up to 115.2 kbaud (E50H5)
  • SKU: E50H2A Category:

    Description

    The E50H2A BACnet MS/TP DIN Rail Meter combines exceptional performance and easy installation to deliver a cost-effective solution for power monitoring applications. Native serial communication via BACnet MS/TP provides complete accessibility of all measurements to your Building Automation System. Built in integrator and power supply for U018 CTs. The E50H2A can be easily installed on standard DIN rail, surface mounted or contained in an optional NEMA 4 enclosure, as needed. The front-panel LCD display makes device installation and setup easy and provides local access to the full set of detailed measurements. A phase alarm pulse output provides additional versatility and a pulse input provides an easy way to incorporate a simple flow sensor to track gas, water, steam, or other energy forms using a BACnet building automation system in addition to full monitoring of electrical energy.
    APPLICATIONS

  • Energy monitoring in building automation systems
  • Energy management
  • Commercial submetering
  • Industrial monitoring
  • Cost allocation
    FEATURES

  • Built in integrator and power supply for U018 CTs
  • DIN rail mounting option…easy installation
  • ANSI 12.20 0.5% accuracy, IEC 62053-22 Class 0.5S…great for cost allocation
  • Separate pulse input and phase loss alarm output…one device serves multiple applications
  • 90-600 VAC…application versatility with fewer models to stock
  • Bright backlit LCD…easy visibility in dark enclosures
  • Compatible with Veris U018 CTs from 20A to5000A…wide range of service types
  • User-enabled password protection…protect from tampering
  • System integration via BACnet MS/TP…convenient compatibility with existing systems
  • Native BACnet MS/TP support (no gateway) with serial rates up to 115.2 kbaud (E50H5)
  • Additional information